Home » Products » Cables » Power Cable » 10kV Aerial Cable ACSR Conductor XLPE Insulated JKLGYJ

10kV Aerial Cable ACSR Conductor XLPE Insulated JKLGYJ

5 0 Reviews
Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Insulated  cables  for  overhead  are  mainly  applied  for  conditions  like  roads  and  parkways  in  cities  and  towns, overhead lines near to buildings, construction sites, overhead lines between towers and poles,etc.

One widely applied series are referred to as Aerial Bunched Cable(ABC), which is usually grouped into two:

- Cables with supporting neutral core: the whole bundle is suspended and carried by the supporting core, whose conductor is usually AAAC or steel strand;

-Self-supporting bundled cable: suspension and carrying of the whole bundle is done by the phase cores.

Bundles can include one or more additional cores for public lighting and/or control purposes.



0kV Aerial Cable ACSR Conductor XLPE Insulated

JKLGYJ

Nominal

Cross-sectional Area

Nominal thickness of insulation

Approx.OD.

Max.Resistance of conductor at 20 ℃

Min.Breaking load of cable

Approx. Weight of completed Cable

mm²

mm

mm

Q/km

N

Kg/km

35/6

3.4

12.70

0.868

11990

285.90

50/8

3.4

13.90

0.641

11020

354.50

50/30

3.4

25.90

0.641

40500

564.50

70/10

3.4

15.50

0.443

22220

450.90

70/40

3.4

27.10

0.443

55390

718.90

95/15

3.4

17.80

0.320

33250

589.10

95/20

3.4

18.30

0.320

35340

623.60

95/55

3.4

27.30

0.320

74200

956.80

12077

3.4

18.30

0.253

26190

589.90

1250/20

3.4

19.10

0.253

38950

690.30

120/25

3.4

19.90

0.253

45480

760.80

120/70

3.4

27.90

0.253

93450

1167.60

150/8

3.4

19.80

0.206

31220

689.10

150/20

3.4

20.50

0.206

44300

787.30

150/25

3.4

20.80

0.206

51400

842.80

150/35

3.4

21.10

0.206

61770

922.70

185/10

3.4

21.80

0.164

38830

832.50

185/25

3.4

22.40

0.164

56450

963.60

185/30

3.4

22.80

0.164

61100

996.50

185/45

3.4

24.10

0.164

76180

1116.80

240/30

3.4

25.30

0.125

71840

1211.10

240/40

3.4

25.90

0.125

79200

1262.20

240/55

3.4

26.70

0.125

97000

1422.30


Code: ABC 0.6/1kV.

Standards:HD 626  S1:1996  Part5-Section D,AMKA(SFS     2200).

Construction: Phase  Conductors:Aluminum conductors with XLPE insulation.

Neutral Messenger:Aluminum conductors.

Application: Aerial Bundled Conductors are used for tributary networks of power buildings and their internal networks.

Installation: These cables are not allowed to be buried, even in conduits.

Dimensions of Phase Conductors

Cross Section

Conductor

Diameter

Thickness of Insulation

Core Diameter

Current Carrying Capacity

Breaking

Load

(mm²)

min.

tolerance

nom.

min.

min.

max.

(A*)

(kN)

(mm)

(mm)

(mm)

(mm)

(mm)


16

4.4

±0.05

1.4


7.1

7.3

70


25

5.9

±0.02

1.4


8.3

9.1

95


35

6.9

±0.02

1.6


9.7

10.5

115


50

8.1

±0.25

1.6


10.8

11.8

140


70

9.7

±0.25

1.8


12.8

13.8

180


120

12.8

±0.30

2.0


16.2

17.4

250


*  Defined  for  ambient  temperature  of 25℃  and  max.conductor  temperature  of 70℃.

Cross Section

Conductor Diameter

Thickness of Insulation

Core Diameter

Current Carrying Capacity

Breaking Load

(mm²)

min.

tolerance

nom.

min.

min.

max.

(A*)

(kN)

(mm)

(mm)

(mm)

(mm)

(mm)


25

5.9

±0.02



5.5

6.3


7.4

35

6.9

±0.02



6.5

7.3


10.3

50

8.1

±0.25



7.6

8.6


14.2

70

9.7

±0.25



9.2

10.2


20.6

95

11.4

±0.30



10.8

12.0


27.9

Dimensions     of     Cable     Bundle

Number of Phase Cores× Cross Section +Public Lighting Conductors

+ Neutral Cross Section

(mm²)

Bundle Diameter

Approx.

(mm)

1×16+25

15

3×16+25

22

4×16+25

22

3×25+35

26

4×25+35

26

3×35+50

30

3×50+70

35

3×70+95

41

3×120+95

47

LV-ABC Lines with Insulated Neutral Messenger

Code: ABC 0.6/1kV.

Standards:HD 626 S1:1996 Part 6-Section E,AMKA(SFS 2200)

Construction: Aluminum conductors with XLPE  insulation.

Application:Aerial Bundled Conductors are used for tributary networks of power     buildings and their internal networks.

Installation:These cables are not allowed to be buried,even in conduits.

Dimensions of Phase Conductors

Cross Section

Conductor

Diameter

Thickness of

Insulation

Core Diameten

Current Carrying Capacity

Breaking Load

(mm²)

min.

max.

nom.

min.

min.

max.

(A*)

(kN)

(mm)

(mm)

(mm)

(mm)

(mm)


16

4.6

5.1

1.2


7.0

7.8



25

5.8

6.3

1.4


8.6

9.4

112


35

6.8

7.3

1.6


10.0

10.9

138


50

7.9

8.4

1.6


11.1

12.0

168


70

9.7

10.2

1.8


13.3

14.2

213


95

11.0

12.0

1.8


14.6

15.7

258


120

12.0

13.1

1.8


15.6

16.7

306


150

13.9

15.0

1.7


17.3

18.6

344


* Defined for ambient temperature of 30℃ and max. conductor temperature of 90℃.

Dimensions of Neutral Messenger Conductors

Cross Section

Conductor

Diameter

Thickness of

Insulation

Core Diameter

Current Carrying Capacity

Breaking

Load

(mm²)

min.

tolerance

nom.

min.

min.

max.

(A*)

(kN)

(mm)

(mm)

(mm)

(mm)

(mm)


54.6

9.2

9.6

1.6


12.3

13.0


16.6

70

10.0

10.2

1.5


12.9

13.6


20.5

95

12.2

12.9

1.6


15.3

16.3


27.5

* Defined for ambient temperature of 30℃ and max.conductor temperature of 90℃.

Dimensions of Cable Bundle

Number of Phase Cores× Cross Section +Public Lighting Conductors

+Neutral Cross Section

(mm²)

Bundle Diameter

Approx.

(mm)

3×25+54.6

30.0

3×35+K×16+54.6

33.0

3×50+K×16+54.6

36.0

3×70+K×16+54.6

37.5

3×70+K×25+54.6

40.0

3×70+K×16+70

41.0

3×95+K×16+70

44.0

3×120+K×16+70

46.0

3×120+K×16+95

47.0

3×150+K×16+70

48.0

3×150+K×16+95

49.0

* Note: K number of public lighting conductors(K can be equal to 0.1.2.or 3).

Code: ABC 11kV.

Standards:SANS 1713.

Construction:Phase  Conductors:Aluminum conductors with XLPE insulation.

Neutral  Messenger:A  stranded  galvanized  steel  conductor  with  XLPE insulation.

Application: The Aerial Bundled Conductors shall suitable for continuous

operation outdoors in tropical areas at altitudes of up to 2200m above sea

level, humidity of up to 90%, average ambient temperature of+30℃ with

a minimum of - 1℃ and a maximum of +4℃ in direct  sunlight, heavy

saline  conditions  along  the  coast  and  isoceraunic  levels  of up  to  180

thunderstorm days per year.

Installation:These cables are not allowed to be buried,even in conduits.


Phase Conductor Characteristics

1

Conductor    size

mm²

70

95

185

2

Diameter    over    conductor.nominal

mm

9.3-10.2

11.6

16.4


3

Thickness   of   dielectric.nominal

mm

3.4

3.4

3.4

Minimum  at  a  point

mm

2.96

2.96

2.96

4

Diameter  over  insulation.  nominal

mm

16.1-17.0

21.3

25.9

5

Diameter  over  semi-conducting  core  screen.  nominal

mm

18.1-19

23.3

27.9

6

Thickness  of  copper  tape.nominal

mm

0.15

1.15

2.15


7

Thickness   of   sheath.nominal

mm

1.8

1.8

1.8

Minimum  at  a  point

mm

1.43

1.43

1.51

8

Catenary   size

mm²

50

50

70

9

Overall   diameter   of   bundle.nominal

mm

55.7

67.8

79.2

10

Nominal  mass

kg/m

2.64

3.25

4.65


Supporting Catenary Characteristics

1

Catenary size

mm²

50

70

2

Number of wires


7

7

3

Wire size(diameter)

mm

3.0

3.6

4

Minimum tensile strength of each wire

kN

9.26

13.13

5

Elongation at break. minimum

%

3.5

4.0


6

Thickness of protective covering




Nominal

mm

1.2

1.2

Minimum at a point

mm

0.96

1.96

7

Impusewhsandvoag        e1.250s


21kV/5min

21kV/5min


Previous: 
Next: 

ABOUT US

Our company is a professional company that engaged in production, sales, technology research, technology development and technical services of electrical system products, power engineering design and construction, electrical products, electrical equipment, sales, installation and technical services of energy storage equipment.

QUICK LINKS

PRODUCTS

CONTACT US

  2201-7&2201-8, Dongjiu Building, No.888 Jiefang East Road, Yixing City, Jiangsu Province
  +86-18020528228
  +86-510-87015096
   +86-18020528228/+86-18761555908
​Copyright © 2023 Jiangsu East Energy Electrical Engineering Co., Ltd.  苏ICP备16064163号-1 Technology by Leadong. Sitemap.

Related Products