Availability: | |
---|---|
Quantity: | |
ZC-3232
ZC-3232 Silane XLPE Compound of Monosil Method for Wire and Cable up to 3kV
This material is a kind of warm water crosslinkable polyethylene insulation compound. It is processed by using high quality polyethylene resin, silane coupling agent, initiator, antioxidant agent, catalyst and other additives. It has an excellent extrusion performance, stable physical and chemical index; Quick extruding speed and smooth surface.
Application: 3kV and below power cable insulation; Maximum working temperature is 90C. Property
Item | Unit | Test method | Standard value | Typical value | |
Tensile strength | MPa | IEC 60811- 1- 1 | ≥ 13.5 | 18.0 | |
Elongation at break | % | ≥350 | 470 | ||
Impact embrittlement performance@-76C | Failure number | Piece | ASTM D746 | ≤15/30 | 0/30 |
After aging @135C, 168h | Tensile strength variation | % | IEC 60811- 1-2 | ± 20 | +6 |
Breaking elongation variation | % | ± 20 | -3 | ||
Hot prolongation@200C, 0.2MPa, 15min | Elongation under the load | % | IEC 60811-2- 1 | ≤ 100 | 55 |
Permanent deformation | % | ≤ 5 | 0 | ||
Dielectric dissipation factor@20C, 50HZ | - | IEC 60250 | ≤0.001 | 0.0001 | |
Relative dielectric constant@20C, 50HZ | - | ≤ 2.35 | 2.25 | ||
Dielectric strength@20C | MV/m | IEC 60243- 1 | ≥ 25 | 37 | |
Volume resistivity@20C | Ω · m | IEC 60093 | ≥ 1 × 1014 | 6 × 1014 | |
Gel content | % | ASTM D2765 | ≥ 60 | 66 |
Processing
Recommend for polyethylene specific extruder. Draw ratio is from 18:1 to 25:1 and other equipment need to be adjusted according to the circumstance.
Zone | Feeding Section | Compression Section | Homogenization Section | Model Section |
Temperature Range C | 160- 180 | 180- 190 | 190-200 | 195-205 |
- Above temperature is only for reference.
Reference cross-linking conditions
For general cable insulation layer (1 mm in thickness) can be cross-linked after bathed in 90C above hot water for 4 hours. If the thickness of insulation is larger, it should be appropriate to extend the bath time. Extended by 1mm/4h or extend the time according to the specific heat for extended data.
Storage
Keep at room temperature; Storage environment should be clean, dry and ventilated; Best use within six months from the date of production; Please use up in 16 hours after bag is opened.
Product packing
25kg in moisture resistant aluminum laminated bags with composite paper bags outside; Palletized bottom.
ZC-3232 Silane XLPE Compound of Monosil Method for Wire and Cable up to 3kV
This material is a kind of warm water crosslinkable polyethylene insulation compound. It is processed by using high quality polyethylene resin, silane coupling agent, initiator, antioxidant agent, catalyst and other additives. It has an excellent extrusion performance, stable physical and chemical index; Quick extruding speed and smooth surface.
Application: 3kV and below power cable insulation; Maximum working temperature is 90C. Property
Item | Unit | Test method | Standard value | Typical value | |
Tensile strength | MPa | IEC 60811- 1- 1 | ≥ 13.5 | 18.0 | |
Elongation at break | % | ≥350 | 470 | ||
Impact embrittlement performance@-76C | Failure number | Piece | ASTM D746 | ≤15/30 | 0/30 |
After aging @135C, 168h | Tensile strength variation | % | IEC 60811- 1-2 | ± 20 | +6 |
Breaking elongation variation | % | ± 20 | -3 | ||
Hot prolongation@200C, 0.2MPa, 15min | Elongation under the load | % | IEC 60811-2- 1 | ≤ 100 | 55 |
Permanent deformation | % | ≤ 5 | 0 | ||
Dielectric dissipation factor@20C, 50HZ | - | IEC 60250 | ≤0.001 | 0.0001 | |
Relative dielectric constant@20C, 50HZ | - | ≤ 2.35 | 2.25 | ||
Dielectric strength@20C | MV/m | IEC 60243- 1 | ≥ 25 | 37 | |
Volume resistivity@20C | Ω · m | IEC 60093 | ≥ 1 × 1014 | 6 × 1014 | |
Gel content | % | ASTM D2765 | ≥ 60 | 66 |
Processing
Recommend for polyethylene specific extruder. Draw ratio is from 18:1 to 25:1 and other equipment need to be adjusted according to the circumstance.
Zone | Feeding Section | Compression Section | Homogenization Section | Model Section |
Temperature Range C | 160- 180 | 180- 190 | 190-200 | 195-205 |
- Above temperature is only for reference.
Reference cross-linking conditions
For general cable insulation layer (1 mm in thickness) can be cross-linked after bathed in 90C above hot water for 4 hours. If the thickness of insulation is larger, it should be appropriate to extend the bath time. Extended by 1mm/4h or extend the time according to the specific heat for extended data.
Storage
Keep at room temperature; Storage environment should be clean, dry and ventilated; Best use within six months from the date of production; Please use up in 16 hours after bag is opened.
Product packing
25kg in moisture resistant aluminum laminated bags with composite paper bags outside; Palletized bottom.